Instrumentations
JTECH Srl, located in Turin, serves as the technical and commercial reference point for NBC Elettronica's load cells, dynamometers, and industrial weighing systems within the Piedmont region.
NBC Elettronica Group specializes in electronic weighing. Their extensive experience enables them to develop a broad range of industrial weighing solutions that address diverse and specific client requirements. Their products are globally recognized for their precision, reliability, and safety.
Instrumentation plays a crucial role in the acquisition, processing, and transmission of signals. It includes analog and digital transmitters, weight indicators, signal conversion modules, load limiters, and flow regulators.
The integration of these components enables real-time monitoring, test automation, and data logging even in complex and high-performance environments.
Main typologies:
| AMAV 02: analog weight transmitter. Power supply: 24 VDC ± 15%. Measurement range: ±1mV/V, ±2mV/V, ±3mV/V selectable via DIP switches. | ![]() |
Learn more... |
| ANA 126R: analog weight transmitter. Power supply: 12 VDC or 24 VDC ± 15%. Measurement range: ±1mV/V, ±2mV/V, ±3mV/V selectable via DIP switches. Outputs: 0–10 V / 0–5 V / 0–20 mA / 4–20 mA. | ![]() |
Learn more... |
| ATM 04 ANA: digital transmitter. Power supply: 24 VDC ± 10%, protected against reverse polarity. Measurement range: from -2.6 mV/V to +2.6 mV/V. | ![]() |
Learn more... |
| ATM 04 CAN OPEN: digital transmitter. Power supply: 24 VDC ± 10%. Measurement range: from -2.6 mV/V to +2.6 mV/V. Interface: CANopen. | ![]() |
Learn more... |
| ATM 04 DEVICENET: digital transmitter. Power supply: 24 VDC ± 10%, protected against reverse polarity; protected with resettable fuse. Measurement range: from -2.6 mV/V to +2.6 mV/V. Interface: DeviceNet. | ![]() |
Learn more... |
| ATM 04 ETHERCAT: digital transmitter. Power supply: 24 VDC ± 10%, protected against reverse polarity; protected with resettable fuse. Measurement range: from -2.6 mV/V to +2.6 mV/V. Interface: EtherCAT. | ![]() |
Learn more... |
| ATM 04 ETHERNET: digital transmitter. Power supply: 24 VDC ± 10%, protected against reverse polarity; protected with resettable fuse. Measurement range: from -2.6 mV/V to +2.6 mV/V. Interface: Ethernet. | ![]() |
Learn more... |
| ATM 04 ETHERNET IP: digital transmitter. Power supply: 24 VDC ± 10%, protected against reverse polarity; protected with resettable fuse. Measurement range: from -2.6 mV/V to +2.6 mV/V. Interface: Ethernet IP. | ![]() |
Learn more... |
| ATM 04 PROFIBUS DP: digital transmitter. Power supply: 24 VDC ± 10%, protected against reverse polarity; protected with resettable fuse. Measurement range: from -2.6 mV/V to +2.6 mV/V. Interface: Profibus DP. | ![]() |
Learn more... |
| ATM 04 PROFINET IO: digital transmitter. Power supply: 24 VDC ± 10%, protected against reverse polarity; protected with resettable fuse. Measurement range: from -2.6 mV/V to +2.6 mV/V. Interface: Profinet IO. | ![]() |
Learn more... |
| ATM 04 RS485: digital transmitter. Power supply: 24 VDC ± 10%, protected against reverse polarity. Measurement range: from -2.6 mV/V to +2.6 mV/V. | ![]() |
Learn more... |
| ATM 05: digital transmitter. Power supply: 10–30 VDC. Measurement range: from -3.9 mV/V to +3.9 mV/V. | ![]() |
Learn more... |
| CPT 02: weight indicator. Power supply: 5 VDC ± 10% with external 230VAC power adapter. Configurable measurement range from 2.5 mV/V to 0.5 V/V. | |
Learn more... |
| DSET 22: load limiter. Power supply: 10–30 VAC / VDC. Measurement range: from -0.1 mV/V to +1.4 mV/V. | ![]() |
Learn more... |
| Profibus Interface: signal conversion module. Power supply: 10–30 VDC. | ![]() |
Learn more... |
| Serial Profinet Interface: signal conversion module. Power supply: 10–30 VDC. | ![]() |
Learn more... |
| IP 65 2 LOAD CELLS: IP 65 junction box. Connections: dual-ferrule spring terminals in stainless steel, pitch 5.08 mm. | ![]() |
Learn more... |
| IP 65 3 LOAD CELLS: IP 65 junction box. Connections: dual-ferrule spring terminals in stainless steel, pitch 5.08 mm. | ![]() |
Learn more... |
| IP 65 4 LOAD CELLS: IP 65 junction box. Connections: dual-ferrule spring terminals in stainless steel, pitch 5.08 mm. | ![]() |
Learn more... |
| RIP H100: weight repeater. Power supply: 100–240 VAC 50/60 Hz. | ![]() |
Learn more... |
| RIP H160: weight repeater. Power supply: 100–240 VAC 50/60 Hz. | ![]() |
Learn more... |
| RIP H60: weight repeater. Power supply: 230 VAC ± 15%, 50/60 Hz. | ![]() |
Learn more... |
| RRF: wireless transmitter. Power supply: 4.5V – 15VDC / USB port. | ![]() |
Learn more... |
| RS 232/485: signal conversion module. Power supply: 5 – 24 VDC. | ![]() |
Learn more... |
| RXDI 02: handheld device. Powered by 3 x 1.5V AA batteries (max autonomy: 150 hours). Measurement range: 2 mV/V. | ![]() |
Learn more... |
| RXDI 02 PORT: handheld device. Powered by 3 x 1.5V AA batteries (max autonomy: 100 hours). Measurement range: 2 mV/V. | ![]() |
Learn more... |
| SA 02: weight indicator. Power supply: 24 VDC / 24 VAC ± 20%. Configurable measurement range from 1 mV/V to 0.5 V/V. | ![]() |
Learn more... |
| SE 01: weight indicator. Power supply: 230 VAC ± 10%. Configurable measurement range from 1 mV/V to 0.5 V/V. | ![]() |
Learn more... |
| SE 03: weight indicator. Power supply: 230 VAC ± 10%, configurable measurement range from 1 mV/V to 0.5 V/V. | ![]() |
Learn more... |
| Serial to Ethernet Bridge: signal conversion module. Power supply: 10 – 30 VDC. | ![]() |
Learn more... |
| SET 07 N: load limiter. Power supply: 20–50 VAC/VDC, protected against reverse polarity. | ![]() |
Learn more... |
| SL 01: weight indicator. Power supply: 24 VDC ± 15%, measurement range: from -3.9 mV/V to +3.9 mV/V. | ![]() |
Learn more... |
| SRQ: weight indicator. Power supply: 24 VDC ± 15%, measurement range: from -3.9 mV/V to +3.9 mV/V. | ![]() |
Learn more... |
| SV 01: weight indicator. Power supply: 230 VAC ± 10%, configurable measurement range from 1 mV/V to 0.5 V/V. | ![]() |
Learn more... |
| TBL 01 BELTER: flow controller. Power supply: 230 / 115 VAC 50/60 Hz (externally accessible 80 mA T fuse). Measurement range: from -3.9 mV/V to +3.9 mV/V. Outputs: 6 relays (NO contact) max 115 VAC / 30 VDC, 0.5 A each. | ![]() |
Learn more... |
| TBL 01 LOSSER: flow controller. Power supply: 230 / 115 VAC 50/60 Hz (externally accessible 80 mA T fuse). Measurement range: from -3.9 mV/V to +3.9 mV/V. Outputs: 6 relays (NO contact) max 115 VAC / 30 VDC, 0.5 A each. | ![]() |
Learn more... |
| TRF: wireless transmitter. Powered by 4 external AA batteries (1.2V Ni-MH or 1.5V alkaline), or 4.5 – 15 VDC. Measurement range: from -3.9 mV/V to +3.9 mV/V. | ![]() |
Learn more... |
| TRF POL: wireless transmitter. Powered by 4 external AA batteries (1.2V Ni-MH or 1.5V alkaline). Measurement range: from -3.9 mV/V to +3.9 mV/V. | ![]() |
Learn more... |
| TS 01: weight indicator. Power supply: 24 VDC (±15%). Measurement range: from -7.8 mV/V to +7.8 mV/V. | ![]() |
Learn more... |
| USB HOST: signal conversion module. Power supply: 10 – 30 VDC. | ![]() |
Learn more... |
| VIS H100: large-digit weight indicator. Power supply: 100 – 240 VAC 50/60 Hz. Measurement range: from -1.5 mV/V to +3.5 mV/V. Digit height: 100 mm. | ![]() |
Learn more... |
| VIS H160: large-digit weight indicator. Power supply: 100 – 240 VAC 50/60 Hz. Measurement range: from -1.5 mV/V to +3.5 mV/V. Digit height: 160 mm. | ![]() |
Learn more... |
| VIS H60: large-digit weight indicator. Power supply: 230 VAC ± 15% 50/60 Hz. Measurement range: from -1.5 mV/V to +3.5 mV/V. Digit height: 60 mm. | ![]() |
Learn more... |